Testing Blog

CVE-2026-116779: FreeSWITCH Inbound SIP MESSAGE Enables Unauthenticated API Command Execution

Written by Uptycs Threat Research | Nov 23, 2026, 10:12:50 AM

Severity: Critical (CVSS 3.1 9.8) · Exploitation: Actively exploited (CISA KEV since 2026-11-09) · Fix available: Yes

Summary

CVE-2026-116779 is a code injection vulnerability in SignalWire FreeSWITCH, an open-source software-defined telecom stack. The flaw resides in the sofia_presence_handle_sip_i_message() function, which incorrectly parses the To-header user field of inbound SIP MESSAGE requests and allows an attacker to select the api chat protocol, routing the message body directly to switch_api_execute(). From that position, an attacker can run arbitrary FreeSWITCH API commands — including operating-system command sinks — with the privileges of the FreeSWITCH daemon. The vulnerability was disclosed on 2026-11-05 and exploitation in the wild has been confirmed; a fix is available in FreeSWITCH 1.11.3.

Technical details

The root cause is improper input validation combined with exposure of a privileged internal API to an external message path (CWE-77, CWE-78, CWE-749). When a SIP MESSAGE arrives, sofia_presence_handle_sip_i_message() splits the To-header user field on a plus sign (+) and treats the left-hand token as a chat protocol selector. No sanitization prevents an attacker from supplying api as that token, which causes the function to dispatch the message body to switch_api_execute() — a sink capable of running OS-level commands. Inbound SIP chat is enabled by default on both the stock internal and external Sofia profiles. The CVSS 3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) reflects that exploitation requires no authentication, no user interaction, low complexity, and is reachable over any network path. Additionally, stock directory accounts without configured password material can be used to satisfy profile-level authentication requirements where it exists, further widening the exposed population. The exact internal call chain beyond the points described in the advisory is not fully public.

Affected products

  • SignalWire FreeSWITCH versions prior to 1.11.3 — fixed in 1.11.3

Impact

  • Unauthenticated remote code execution. An attacker who can send a SIP MESSAGE to an exposed FreeSWITCH instance can execute arbitrary operating-system commands with daemon-level privileges, potentially achieving full host compromise.
  • Configuration and credential disclosure. FreeSWITCH configuration files, directory credentials, and other sensitive material stored on the host are accessible to an attacker exploiting this flaw.
  • Arbitrary call control. The FreeSWITCH API exposes full call-control primitives; an attacker can originate, intercept, redirect, or terminate active calls.
  • Automatable, wide-blast-radius exploitation. CISA's SSVC assessment rates this vulnerability as automatable with total technical impact, meaning mass exploitation at scale is feasible with minimal per-target effort.

Exploitation status

Active exploitation of CVE-2026-116779 has been confirmed in the wild. CISA added it to the Known Exploited Vulnerabilities catalog on 2026-11-09, with a required remediation deadline of 2026-11-12 for Federal Civilian Executive Branch agencies; all organizations should treat this timeline as a practical benchmark for prioritization. No public proof-of-concept reference is included in available sources, but the confirmed in-the-wild activity and CISA's automatable rating mean that patch priority should be treated as immediate for any internet-exposed FreeSWITCH deployment.

Recommended actions

  1. Upgrade FreeSWITCH to version 1.11.3 immediately. This is the only fully remediated state; apply the vendor patch before any other mitigation.
  2. Restrict SIP MESSAGE traffic at the network perimeter. Use firewall ACLs or a Session Border Controller (SBC) to limit inbound SIP traffic — particularly MESSAGE requests — to explicitly trusted source addresses until patching is complete.
  3. Restrict access to the FreeSWITCH Event Socket (port 8021). Ensure this port is not reachable from untrusted networks, as post-exploitation may target it for persistent access.
  4. Rotate all credentials and API keys stored in FreeSWITCH configuration. Files such as vars.xml and directory XML files may have been read by an attacker; treat them as compromised and rotate accordingly.
  5. Review FreeSWITCH process logs and host telemetry for signs of compromise. Look for unexpected child processes spawned by the FreeSWITCH daemon (e.g., sh, bash, curl, wget), anomalous outbound network connections originating from the FreeSWITCH process, and new or modified files under FreeSWITCH configuration and script directories.
  6. Conduct forensic triage per CISA guidance. CISA's KEV entry references specific Forensics Triage Requirements; any FreeSWITCH host that was internet-exposed prior to patching should be assessed for compromise before being returned to service, and rebuilding from a known-good baseline should be considered if indicators are found.

How Uptycs helps

Uptycs vulnerability management continuously identifies hosts, containers, and cloud workloads running affected versions of FreeSWITCH so security teams can immediately prioritize patching across their entire environment. Uptycs Threat Research continues to monitor CVE-2026-116779 for changes in exploitation activity and will update this bulletin if new indicators or attacker techniques are observed.

References